Omicron CMC 500

  • For applications with high accuracy and amplitude requirements
  • Up to 10 currents and 7 voltages
  • Three-winding transformer protection, sync check, energy meter, and much more
  • Weight: 32kgs

View Data Sheet

Omicron CPC 100

  • Versatile Testing: Performs tests on power/instrument transformers, circuit breakers, rotating machines, grounding, and cables.
  • High Power: Offers a strong integrated source (up to 5 kVA, 800A/2kV) for primary injection
  • Consolidated Device: Replaces several individual test sets, reducing equipment, training, and transport costs.
  • Weight: 43kgs
  • View Data Sheet

B2 Electronics HVA28TD

  • Portable VLF Test System and DC Hipot with Tan Delta.
  • Output Voltage: 29kV peak, 20kVrms
  • Output Load 0.9µF@0.1Hz@32.3kVrms
  • Weight 39kgs

View Data Sheet

hva60

B2 Electronics HVA60

  • Portable VLF Test System and DC Hipot.
  • Output Voltage: 62kV peak, 44kVrms
  • Output Load 1µF@0.1Hz@44kVrms
  • Weight 57kgs

View Data Sheet

B2 Electronics HVA68TD

  • Portable VLF Test System and DC Hipot with Tan Delta
  • Output Voltage: 68kV peak, 48kVrms
  • Output Load: 2µF@0.1Hz@44kvrms
  • Weight: 63kgs

View Data Sheet

2293

Haefely WA2293

  • Automatic Transformer Test System
  • 3 Phase testing of Distribution/Power Transformer and CT/VT
  • All testing parameters available
  • Weight 18kgs

View Data Sheet

Midas_micro_2883

Haefely (Tettex) MIDAS Micro 2883

  • All in one 12kV Tan Delta Test System
  • Smallest and most compact insulation diagnostic test set on the market
  • 7 inch colour touch screen user interface
  • Weight 25kgs

View Data Sheet

HV Diagnostics Digi-bridge

  • Cable/Jacket/Sheath Fault Locator and DC Hipot
  • Output: 12kV, 30µF
  • Weight 12.8kgs
  • IP65 Rating

View Data Sheet

Ez

HV Diagnostics EZ-Cable ID

  • Simultaneous single and three phase identification
  • Use on energised or de-energised cables, single or multi-core
  • Power with battery or mains
  • Direct input to cable or inductive clamps x 2

View Data Sheet

Aqua Tronics EG-3000 and EG3000T

  • Underground Cable Fault Locator with Automatic Cable-Saving Voltage Control
  • High current up to 2.2 amps available
  • High resistance cable thumper
  • High voltage up to 3kV output
  • Battery operated unit with built-in cable tracer
  • Weight 14kg

View Data Sheet

B2 Electronics HVA34

    • Output voltage 34 kVpeak , 24 kVrms
    • Pure sinusoidal output voltage (load-independent)
    • Internal TD measurement with high accuracy (1 x 10-4)
    • 0.8 μF @ 0.1 Hz @ 24 kV rms
    • Highest test capacity of 10 μF
    • Ultra light and compact weight (20 kg)
    • View Data Sheet
Thumper

Hipotronics X-Wave Portable Thumper

  • Output: 500V-10kV,12.5mA, 350J
  • Modes: Arc Reflection (High voltage TDR), Direct TDR (Low voltage TDR), DC Hipot, Capacitive Discharge (Thump)
  • Weight: 19kgs

View Data Sheet

Omicron CT Analyzer

  • Injects low test signals into secondary side of the CT
  • Determines the CT‘s equivalent circuit parameters
  • Identifies all relevant CT performance parameters
  • Displays all relevant parameters of the CT and its accuracy at different currents and burdens

View Data Sheet

Megger MIT1025 – Advanced IR Tester

  • RE>Act mode enhanced accuracy and safety
  • PI predictor function (PIp)
  • PDC test capability Measures up to 30 TΩ
  • Safety rated up to CAT IV 1000 V to 3000 m
  • Up to 6 mA noise rejection

View Data Sheet

Megger MOM3 With Probes & Clamps

  • Test current up to 300 A
  • Battery operated
  • Lightweight – 1.15 kg Auto
  • range: 0.1 µΩ to 3000 mΩ Optional wifi communication to EGIL 200*
  • Complies with IEEE and IEC standards

View Data Sheet

Doble F6150SV – Protection Relay Tester

  • Performs standard relay calibration and verification testing of high burden and microprocessor relays
  • Maximum of 12 sources (six voltage, six current) configurable for bench testing and proof-of-concept testing for complicated relaying schemes
  • Control all sources from a tablet device for basic, manual protection testing

View Data Sheet

Megger DLRO10HD – Advanced Micro-ohmeter

  • Onboard memory storage for test results up to 200 records
  • Download to PowerDB
  • Interchangeable test lead terminations
  • High or low output power selection for condition diagnosis
  • Operates from rechargeable battery or AC mains supply

View Data Sheet

Omicron SB1 (Switch Box for CPC 100)

  • Time saving: Rewiring no longer necessary
  • Safety: one-time connection of cables
  • Minimization of measurement errors: Fully automated testing

View Data Sheet

Omicron Cibano 500 – Advance

  • 3-in-1 system: micro-ohmmeter, timing analyzer, and AC/DC power supply
  • One system for medium- or high-voltage circuit breakers with live-, dead-tank or GIS-design
  • Low wiring effort
  • One clear report for all tests
  • Circuit Breaker Testing Library (CBTL)
  • Lightweight test system (20 kg / 44.1 lbs)

View Data Sheet

Omicron CMC 356 61850

  • Powerful current sources for testing even high-burden electromechanical relays
  • High current amplitudes for 5 A relay testing
  • High accuracy and versatility for testing static and numerical relays of all types
  • Integrated network for testing IEC 61850 IEDs
  • 10-channel analog measurement and transient recording functionality (option)
  • View Data Sheet

b2 PDTD60-2

The PD60-2 and PDTD60-2 offer both portable and built-in solutions for diagnostics of medium voltage cables, rotating machines and transformers. Diagnostics of medium and high voltage cables provides the opportunity for early detection of vulnerabilities and preventative maintenance work to be carried out before the cable fails in service.

View Data Sheet

Megger EZ Thump 12kV

  • Compact, lightweight, all-in-one, rugged portable cable fault locating system
  •  Battery and AC line operation; field-replaceable battery
  •  Automatic cable end identification
  • Automatic ARM fault pre-location with multishot technology

View Data Sheet

Megger TDR 2050

  • CAT IV 600 V input protection
  • IP54 rating offers real life working
  • ‘Auto Setup’ mode for instant, easy use
  • ‘AutoFind’ and ‘FindEnd’ functions helps find the fault fast
  • Trace tagging facility that allows a name to be saved with the trace
  • Distance dependent gain to counteract signal attenuation

View Data Sheet

Megger MFM 10 Seba

  • Test voltage up to ±10 kV DC
  • Up to 750 mA continuous current, also suitable for burning
  • Adjustable current limiter
  • Bipolar measurement for the highest accuracy
  • Only one single removable high voltage connection cable needed
  • Easy Go operation via jogdial and touch screen
  • Automatic measurement and protocolling
  • View Data Sheet

Fluke 1777 Power Quality Analyzer

Fluke 1770 Series Three-Phase Power Quality Analyzers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord

.

View Data Sheet

Megger DET 2/3 Earth Tester

 

  • High resolution of 1 mΩ, ideal for large earth systems
  • Versatile tests modes
  • High accuracy for earth/ground electrode grid and soil resistivity tests
  • Rechargeable battery power that can last all day with a fast re-charge (up to 10 hours)
  • Robust instrument with IP65 protection
  • Automatic test frequency selection, with filters and high current features
  • Diagnostic trace display
  • Data storage
  • Large colour display that shows numeric and graphical results
  • Optional earth testing kit (ETK) available

View Data Sheet

Phenix 6CP50/10-3

  • Main power circuit breaker switch (with indicator)
  • External warning circuit provision for safety devices such as flashing light
  • High Voltage ON/OFF pushbuttons with indicators
  • Emergency off pushbutton (Locking)
  • Manual control of output voltage
  • Zero Start interlock
  • External interlock provision
  • Overload circuit adjustable from 10% to 110% of rated current
  • Output overload indicator with reset button

View Data Sheet

HVI PFT503 50kV Hipot

  • Convenient one-piece field portable design
  • Secondary connected 2 Range Voltmeter: 0 – 25 / 50 kV AC
  • 3 Range Current Meter: 0 – 1 mA AC with x1, x10, and x100 multipliers
  • Fixed overload set to 120% of variable transformer rated output current
  • Transit protected meters prevent meter damage between test sites
  • Guard/Ground circuit for accurate leakage current measurement
  • 20 ft shielded output and return cables
  • View Data Sheet

Terasaki OCR Checker TNS-3

Looking for reliable electrical testing equipment? Hire the Terasaki OCR Checker TNS-3 for precise field-testing, maintenance, and troubleshooting of Terasaki air circuit breakers (ACBs) and protection relays.Key Features & Capabilities

.

View Data Sheet

Schneider LV Interface Test Kit (LV485500)

 

  • Hire Schneider LV Interface Test Kit (LV485500) | Secondary Injection & Circuit Breaker Testing

    Looking for a reliable solution to test and configure Schneider low-voltage circuit breakers? Hire the Schneider Electric LV485500 Service Interface Test Kit for advanced field testing, secondary injection verification, and protection parameter configuration. Driven by the EcoStruxure Power Commission software via USB, this service interface replaces legacy test sets (such as the 33595 Full Function Test Kit / FFTK) to deliver complete diagnostic and maintenance capabilities.Key Features & Capabilities

View Data Sheet

b2 Electronics HVA120

Looking for a high-performance solution for field testing medium and high-voltage cables? Hire the b2 electronics HVA120 VLF High Voltage Test Set for precise Very Low Frequency (VLF) withstand testing, DC hipot testing, sheath integrity verification, and sheath fault location. Engineered with an industry-leading power-to-weight ratio, the HVA120 delivers continuous output up to 120 kVpeak / 85 kVrms without thermal limitations, making it the ideal test set for medium-voltage cable networks up to 69 kV in accordance with IEEE 400.2 and IEC standards. Key Features & Capabilities

View Data Sheet

Omicron TD15

Hire Omicron CP TD15 Tan Delta Test Set | High-Voltage Power Factor & Capacitance Diagnostics

Looking for a precise diagnostic solution to assess the insulation health of your high-voltage assets? Hire the Omicron CP TD15 Tan Delta / Power Factor Test Set for advanced capacitance, dissipation factor (tan δ), and dielectric loss measurements. Designed to operate as a high-voltage accessory for OMICRON control units (such as the CPC 100, TESTRANO 600, or CPC 80), the CP TD15 generates test voltages up to 15 kV to provide laboratory-grade diagnostic precision even in environments with severe electromagnetic interference.Key Features & Capabilities

Omicron Testrano 600

Key Features & Capabilities
  • Three-Phase Testing: Energizes all three phases simultaneously, cutting standard testing time by up to two-thirds compared to conventional single-phase test sets. [1, 2]
  • Single Connection Setup: Requires only a single set of connections to perform multiple tests without repeatedly rewiring the transformer. [1, 2]
  • Supported Tests:
    • Transformer Turns Ratio (TTR)
    • DC and Dynamic Winding Resistance (DRM)
    • Demagnetization
    • Short-Circuit Impedance / Leakage Reactance
    • Frequency Response of Stray Losses / Sweep Frequency Response Analysis (SFRA)
    • On-Load Tap Changer (OLTC) scan and vector group checks

.

View Data Sheet

B2 PDTD68

  • Get to know the pdtd68

    The PDTD68 is an integrated VLF diagnostics system specially designed for the use with HVA VLF test sets. Thanks to its practical design and the single fiber optic interface to the PC it enables a simple and safe measurement setup, which can be built up very quickly.

    A large 22 nF coupling capacitor, a built-in filter device and a newly developed data acquisition unit ensure sensitive and accurate PD measurements.

    The PDTD68 is also equipped with a battery supply, which allows use in locations without a permanent power source. It can just as easily be powered and charged via USB-C (PD 3.0).

View Data Sheet

Fluke 1748

The Fluke 1748 logs over 500 different parameters for each averaging period. This allows you to analyze power quality in detail and to correlate intermittent events with detailed waveform data, helping to identify the root cause of disturbances. For basic power quality logging, the Fluke 1746 captures all relevant power parameters for performing energy saving studies and electrical network planning with a full upgrade option to 1748 available. For simple load and energy studies the Fluke 1742 offers optimal performance in a rugged package and can be upgraded to 1746, or complete 1748, functionality.

National and international standards

View Data Sheet

Fluke 1738

Key features

  • Versatile, three-phase power loggers for conducting energy, load and power quality studies.
  • Automatically capture and log voltage, current, power, harmonics and associated power quality values, and capture dips, swells, and inrush currents with event waveform snapshots and high-resolution RMS profiles.
  • Convenient instrument powering directly from the measured circuit
  • Download and analyze every detail of energy consumption and power quality state of health with our automated reporting.

Megger Torkel 950

About the product

The TORKEL900 series of battery discharge test systems are Megger’s fourth generation of battery discharge analysers. Discharge testing is the only test method that provides a comprehensive insight into battery capacity, and is therefore an essential part of vigorous battery maintenance programmes.

Tests with the TORKEL900 series can be conducted at constant current, constant power, constant resistance, or in accordance with a pre-selected load profile. What’s more, if you connect the BVM battery voltage monitor to a TORKEL900 unit, the TORKEL becomes a complete standalone discharge test system.

.

View Data Sheet

Hioki 3554

  • Key Features

    • Measurement circuit that’s more resistant to noise than previous models
    • Instantaneously diagnose degradation (PASS, CAUTION FAIL) by measuring internal resistance and voltage
    • Increased measurement efficiency thanks to new compact, lightweight 

View Data Sheet

Phenix BK130 PD Free

Features

  • Main power circuit breaker switch (with indicator)
  • External warning circuit provision for safety devices such as flashing light
  • High Voltage ON/OFF pushbuttons with indicators
  • Emergency Off pushbutton (Locking)
  • Manual control of output voltage
  • Zero Start interlock
  • External interlock provision
  • Overload circuit adjustable from 10% to 110% of rated current
  • Output overload indicator with reset button
  • Slow and fast acting transient protection on all meters and relays
  • Digital, LCD, multi-range metering
  • Digital timer with audible alarm
  • Guard mode for accurate current measurements

View Data Sheet

Phenix 6CP120 PD Free

This portable rugged line of AC high voltage test equipment is ideally suited for use in the field or in the laboratory. The 6CP and 6CB line offers a complete test system in a mobile package. All units use a combination control and regulator enclosure and a separate high voltage section.

The 6CP system is equipped with advanced digital metering, and control and protection devices which are easy to use and provide the operator with all necessary information to safely operate the system.

The 6CB system is equipped with a 7” Full-Color Touch- Screen display with auto-ranging voltage and current meters plus many other additional features.

Omicron CPCU1

The CP CU1 is a high-power coupling unit that enables safe and reliable testing of power lines and grounding systems under real grid conditions. When used with the CPC 100, the CP CU1 provides controlled signal injection with up to 5 kVA output, ensuring stable measurements even on long lines. Its galvanic isolation and robust safety concept allow a secure connection to de-energized lines, even in the presence of induced voltages from neighboring active systems. Combining it with the CP GB1 grounding box safely dissipates fault currents up to 30 kA.

.

View Data Sheet

  • Omicron HGT1 PTM

  • The HGT1 is a handheld solution for measuring step and touch voltages and supporting ground impedance/fall-of-potential testing. Using it with CPC 100 or COMPANO 100 and PTM enables safe, frequency-selective measurements, even in noisy environments. Its high sensitivity and standard-compliant workflows, in accordance with EN 50522 and IEEE 80 ensure reliable results for commissioning, maintenance, and validation of grounding systems.

View Data Sheet

Terasaki ANU1 Ocr Checker

Key Functions
  • Long Time-Delay Trip: Checks pickup current and time delay.
  • Short Time-Delay Trip: Verifies short-circuit delay performance.
  • Instantaneous Trip: Tests instantaneous pickup current and trip operation.
  • Ground Fault (GF) Trip: Validates ground fault protection functions.
  • Pre-Trip Alarm: Tests pre-trip alarm pickup functional lit